Locally refined SARS-CoV-2 BA-2.86 Spike receptor binding domain (RBD) complexed with angiotensin converting enzyme 2 (ACE2)
ELECTRON MICROSCOPY
| Sample | 
|---|
| BA-2.86 variant SARS-CoV2 S protein complexed with angiotensin converting enzyme 2 (ACE2) | 
| Sample Components | 
| Angiotensin converting enzyme 2 (ACE2) | 
| BA-2.86 variant SARS-CoV2 S protein | 
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE | 
| Vitrification Instrument | |
| Cryogen Name | ETHANE | 
| Sample Vitrification Details | |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE | 
| Number of Particles | 15883 | 
| Reported Resolution (Å) | 3.7 | 
| Resolution Method | FSC 0.143 CUT-OFF | 
| Other Details | CryoSPARC. | 
| Refinement Type | |
| Symmetry Type | POINT | 
| Point Symmetry | C1 | 
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (8CIM, 8ASY, 8IOV) | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | OTHER | ||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | Phenix real space refinement with manual checks using coot. | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | FEI FALCON IV (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 50 | ||||||||
| Imaging Experiment | 1 | 
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS | 
| Minimum Defocus (nm) | 800 | 
| Maximum Defocus (nm) | 2600 | 
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2.7 | 
| Imaging Mode | BRIGHT FIELD | 
| Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER | 
| Nominal Magnification | 165000 | 
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN | 
| Acceleration Voltage (kV) | 300 | 
| Imaging Details | 
| EM Software | ||
|---|---|---|
| Task | Software Package | Version | 
| PARTICLE SELECTION | cryoSPARC | v.4.3.1 | 
| IMAGE ACQUISITION | EPU | |
| CTF CORRECTION | cryoSPARC | v.4.3.1 | 
| MODEL FITTING | Coot | |
| MODEL FITTING | PHENIX | |
| INITIAL EULER ASSIGNMENT | cryoSPARC | |
| FINAL EULER ASSIGNMENT | cryoSPARC | v.4.3.1 | 
| CLASSIFICATION | cryoSPARC | v.4.3.1 | 
| RECONSTRUCTION | cryoSPARC | v.4.3.1 | 
| MODEL REFINEMENT | PHENIX | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | Determined using cryoSPARC live patch CTF correction. | 504319 | ||